Description
The Model 4500Ti is designed specifically for use in highly corrosive environments such as landfills and leach fields. Also used in critical areas where long-term survivability is essential, for example, as in nuclear waste repositories and aggressive mine tailings. All exposed surfaces are made from titanium.*
Spesification
| Standard Ranges¹ |
−100 to 350, 700 kPa; 1, 2, 3, 5, 7.5 MPa
|
| Over Range | 2 × rated pressure |
| Resolution | 0.025% F.S. (minimum) |
| Accuracy | ±0.1% F.S. |
| Linearity | <0.5% F.S. (±0.1% F.S. optional) |
| Temperature Range² | −20°C to +80°C |
| Length × Diameter | 125 × 25.4 mm |