Description
Some measurement tasks require large measuring ranges or a large measurement distance from the target object to be measured. For these types of applications, Micro-Epsilon offers Long Range laser sensors that combine high accuracy with a large measurement distance.
Spesification
| Model | ILD1710-50 |
| Measuring range | 50mm |
| Start of measuring range | 550mm |
| Midrange | 575mm |
| End of measuring range | 600mm |
| Linearity |
50µm |
| ≤±0.1% FSO | |
| Resolution |
7.5µm |
| 0.015% FSO (at 2.5kHz without averaging) | |
| Measuring rate | 2.5kHz / 1.25kHz / 625Hz / 312.5Hz (adjustable) |
| Permissible ambient ligh | 10,000lx |
| Spot diameter SMR | 400 x 500µm |
| Spot diameter MMR | 400 x 500µm |
| Spot diameter EMR | 400 x 500µm |
| Light source | semiconductor laser <1mW, 670nm (red) |
| Laser protection class | Class 2 according to DIN EN 60825-1 : 2008-05 |
| Protection class | IP65 |
| Temperature stability | 0.01% FSO/°C |
| Operating temperature | 0°C ... 50°C |
| Storage temperature | -20°C ... 70°C |
| Output Analog | 4 ... 20mA (0 ... 10V) |
| Output Digital | RS422 / USB (optional with cable PC1700-3/USB) |
| Output Switching outputs | 1 x error or 2x limit values (configurable |
| Switching input | Laser ON-OFF / Zero |
| Operation | via membrane keypad on sensor or via PC with ILD 1700 tool |
| Power supply | 24VDC (11 … 30 VDC), max. 150mA |
| Sensor cable | standard: 0.25 m - integrated |
| Synchronization | possible for simultaneous or alternating measurements |
| Vibration | 2g / 20 ... 500Hz |
| Shock | 15g / 6ms |
| Weight Sensor | approx. 800g |
| Model | ILD2310-10 | ILD2310-20 | ILD2310-40 | ILD2310-50 |
| Measuring range 1) | 10 (5)mm | 20 (10)mm | 40 (20)mm | 50 (25)mm |
| Start of measuring range | 95 (100)mm | 90 (100)mm | 175 (195)mm | 550 (575)mm |
| Midrange | 100 (102.5)mm | 100 (105)mm | 195 (205)mm | 575 (587.5)mm |
| End of measuring range | 105 (105)mm | 110 (110)mm | 215 (215)mm | 600 (600)mm |
| Linearity |
3µm | 6µm | 12µm | 50µm |
| ≤±0.03% FSO | ≤±0.03% FSO | ≤±0.03% FSO | ≤±0.1% FSO | |
| Resolution |
0.5µm | 1µm | 0.6µm | 7.5µm |
| 0.005% FSO |
0.005% FSO (at 10kHz without averaging) |
0.0015% FSO | 0.015% FSO | |
| Measuring rate | switchable (software) 49.14 / 30 / 20 / 10 / 5 / 2.5 / 1.5kHz (49.14kHz with reduced measuring range) | |||
| Permissible ambient light | 10,000…40,000lx | |||
| 400 x 500µm | 200µm | 230µm | 400 x 500µm | |
| 400 x 500µm | 60µm | 210µm | 400 x 500µm | |
| 400 x 500µm | 200µm | 230µm | 400 x 500µm | |
| Light source | laser diode (670nm) class 2 | |||
| Protection class | IP65 | |||
| Operating temperature | 0°C ... +50°C | |||
| Storage temperature | -20°C ... +70°C | |||
| -20°C ... +70°C |
Ethernet / EtherCAT RS422 analog output via CSP2008 / C-Box |
|||
| Inputs |
Laser on/off Sync/Trigger input |
|||
| Power supply | 24 VDC (11 … 30V); PV < 3W | |||
| LED | status / power / Ethernet / EtherCAT | |||
| Sensor cable | standard: 0.25m - integrated | |||
| Synchronization | possible for simultaneous or alternating measurements | |||
|
Electromagnetic compatibility (EMC) |
EN 61326-1: 2006-10 DIN EN 55011: 2007-11 (group 1, class B) EN 61 000-6-2: 2006-03 |
|||
| Vibration | 2g / 20 ... 500Hz | |||
| Shock | 15g / 6ms / 3 axes | |||