Description
Key Features
• For use with data collector
• AC velocity output
• Low smoke, halogen free cable
Vibration sensor should be firmly fixed to a flat surface
(spot face surface may be needed to be produced and
cable anchored to sensor body.)
Industries
Building services, Pulp and Paper,
Mining, Metals, Utilities, Automotive,
Water, Pharmaceutical
Feature
R
Spesification
Technical Performance
|
Mounted Base Resonance |
see ‘How To Order’ table (nominal) |
|
Sensitivity |
see: ‘How To Order’ table ± 10% Nominal 80Hz at 72°F |
|
Frequency Response |
180cpm (3Hz) to 270kcpm (4.5kHz) ± 10%
120cpm (2Hz) to 360kcpm (6kHz) ± 3dB
|
|
Isolation |
Base isolated |
|
Range |
see: ‘How To Order’ table |
|
Transverse Sensitivity |
Less than 5% |
Mechanical
|
Case Material |
Stainless Steel |
|
Sensing Element/Construction |
PZT/Compression |
|
Mounting Torque |
5.9ft. lbs |
|
Weight |
4.4 oz. (nominal) |
|
Maximum Cable Length |
3,280 ft |
| Standard Cable Length |
16 ft |
| Sheilded Cable |
Flame Retardant - length to be specified with orde |
|
Mounting Threads |
see: ‘How To Order’ table |
Electrical
|
Electrical Noise |
0.1mg max |
|
Current Range |
0.5mA to 8mA |
|
Bias Voltage |
10 - 12 Volts DC |
|
Settling Time |
2 seconds |
| Output Impedance |
200 Ohms max |
|
Case Isolation |
>10
8
Ohms at 500 Volts
|
Environmental
|
Operating Temperature Range |
-40 to 212°F |
|
Sealing |
IP65 |
|
Maximum Shock |
5000g |
|
EMC |
EN61326-1:2013 |