Description
EM-5P portable gas monitoring system mainly consists of gas monitoring sensors (SO2, NOx, CO, CO2), sample conditioning unit, sampling unit and heat tracing pipe. The main structural parts include gas sampler and pipeline, sample preconditioning unit and gas analyzer. It is equipped with android
touch screen, having big data storage; with multi-port output; It also has a micro printer for real-time monitoring data.
Feature
- Low detection limit and temperature-drift;
- Getting NOx by directly measuring NO and NO2 which without NO2→NO converter;
- Not affected by the interference of background elements such as dust and H2O;
- No optical moving parts, high reliability, no interference to the measurement by field;
- Good portability and mobility.
Spesification
| Analyzer mode: | Normal Temperature-Condensation Water Removal/High Temperature-Full Temperature |
| Principle: | UV DOAS (SO2, NO), electrochemistry (O2), electrochemistry/TD-LAS (CO), infrared (CO2) |
| Response Time: | ≤90s (T90) |
| Warm-up Time: | normal temperature 10 minutes/high temperature 40 minutes |
| Power Supply: | 220VAC±22V, normal temperature 50W/high temperature 350W |
| Range: | 0~50~1500mg/m3 (SO2/NO/NO2) , 0~25% (O2) , 0~500~10000ppm(CO) ,0~65% (CO2) |
| Linearity Error: | ≤2%F.S. |
| Zero Drift: | ≤±2%F.S./24h |
| Span Drift: | ≤±2%F.S./24h |
| Working Temp.: | 5oC~45oC |
| Working Humidity: | 0~85%RH |
| Dimension: | 498mm×182mm×236mm |
| Weight: | about 12kg |