Description
Non-contact eddyNCDT 3300 eddy current displacement sensors are designed for use in factory automation, for machine monitoring, for quality control and quality assurance. More than 80 differentes sensors models are available.
Spesification
| Controller | DT3300 | DT3301 |
| Linearity | ≤0.2 % FSO | ≤0.2 % FSO |
| Resolution up to 25Hz | ≤0.005 % FSO (≤0.01 % FSO using ES04, ES05 and EU05) | ≤0.005 % FSO (≤0.01 % FSO using ES04, ES05 and EU05) |
| Resolution up to 2.5kHz | ≤0.01 % FSO | ≤0.01 % FSO |
| Resolution up to 25 / 100kHz | ≤0.2 % FSO | ≤0.2 % FSO |
| Bandwidth | selectable 25kHz / 2.5kHz / 25Hz (-3 dB); 100kHz for measuring ranges ≤1mm | selectable 25kHz / 2.5kHz / 25Hz (-3 dB); 100kHz for measuring ranges ≤1mm |
| Temperature compensation | 10 ... 100°C (option TCS: -40 ... 180°C) | 10 ... 100°C (option TCS: -40 ... 180°C) |
| Temperature range controller | 5 ... 50°C | 5 ... 50°C |
| Output | selectable 0 ... 5V / 0 ... 10V / ±2.5V / ±5V / ±10V (or inverted) / 4 ... 20mA (load 350 ohm) | selectable 0 ... 5V / 0 ... 10V / ±2.5V / ±5V / ±10V (or inverted) / 4 ... 20mA (load 350 ohm) |
| Power supply | ≤12VDC / 100mA, 5.2VDC / 220mA | 11 - 32VDC / 700mA |
| Synchronization | via cable PSC 30 (accessories) | via cable E SC 30 (accessories |
| Electromagnetic compatibility | acc. to EN 50081-2 / EN 61000-6-2 | acc. to EN 50081-2 / EN 61000-6-2 |
| Controller functions | limit switches, auto-zero, peak-to-peak, minimum, maximum, average, storage of 3 configurations (calibrations) | limit switches, auto-zero, peak-to-peak, minimum, maximum, average, storage of 3 configurations (calibrations) |