About Us  |   Contact Us   |   Experiences
Home   »   Produk   »   Brand   »   BENTLY NEVADA   »   Sensors and Transducers   »   Acceleration & Velocity
 
Banner Customer Service
 
Banner_Presentasi_Testindo
1

200350 and 200355 Accelerometers

 

The 200350 and 200355 Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster Pro Constant Current Direct Input Card 149811-02 and the Seismic Direct Input Card 164746-01. These transducers can also be used with a number of other Bently Nevada products, including 1900 Series, ADAPT.wind, 3500 Series, Snapshot IS and Snapshot CE.

The 200350 and 200355 Accelerometers are contained within a hermetically sealed, stainless steel case. The design provides an extremely rugged transducer, well suited for harsh industrial environments. Each transducer’s top mounted, 2-pin connector (MIL-C-5015) allows for easy installation and removal of the interconnecting signal cable. A ¼-28 threaded hole on the bottom of the casing accommodates multiple mounting options.The 200350 and 200355 Accelerometers contain a piezoelectric sensing device, which generates charge when subjected to vibration.

This charge is then converted electronically to a differential voltage signal, which is proportional to the acceleration that is parallel to the sensitive axis of the transducer.


Spesification

Electrical

 

English Units SI Units

Sensitivity

  200350 (±20%)

  200355 (±  5%)

10.2 mV/(m/s2) (100 mV/g) 10.2 mV/(m/s2) (100 mV/g)

Frequency Range   

  200350 (± 3dB)

  200355 (± 3dB)

 

30 to 600,000 cpm

12 to 600,000 cpm

 

0.5 to 10,000 Hz

0.2 to 10,000 Hz

Temperature Sensitivity See Graph See Graph
Measurement Range ± 50 g ± 490 m/s2

Transverse Sensitivity

  200350

  200355

 

= 7%

= 5%

 

= 7%

= 5%

Amplitude Linearity ± 1% ± 1%

Mounted Resonant Frequency

  200350

  200355

 

1500 kcpm

1250 kcpm

 

25 kHz

20.8 kHz

Broadband Electrical Noise (1-10kHz)

  200350

  200355

 

350 µg

50 µg

 

3434 µm/s2

491 µm/s2

Output Bias Voltage 8 to 12 VDC 8 to 12 VDC
Excitation Voltage 18 to 28 VDC 18 to 28 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA

Settling Time (within 1% of bias)

  200350

  200355

 

= 2.0 sec

= 5.0 sec

 

= 2.0 sec

= 5.0 sec

Output Impedance

  200350

  200355

 

< 150 ohms

< 100 ohms

 

< 150 ohms

< 100 ohms

Discharge Time Constant

  200350

  200355

 

= 0.3 sec

= 0.8 sec

 

= 0.3 sec

= 0.8 sec

Electrical Isolation (Case)

 > 108 ohms

 > 108 ohms

Environmental

Operating Temperature Range -65 to +250 ºF -54 to +121 ºC
Shock Survivability 5,000 g pk 49,050 m/s2 pk
Relative Humidity

100% relative, condensing, non-submerged


Enclosure Rating IP68 IP68

Physical

Size (Hex x Height)

  200350

  200355

 

11/16 in * 1.65in

7/8in * 2.06in

 

18 mm * 42.2 mm

22mm * 52.3mm

Weight

  200350

  200355

 

1.8 oz

3.3 oz

 

51 gm

94 gm

Mounting Thread 1/4 - 28 Female 1/4 - 28 Female
Mounting Torque (Max) 2 to 5 ft*lb 2.7 to 6.8 N*m
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Stainless Steel Stainless Steel
Sealing Welded Hermetic Welded Hermetic
Electrical Connector 2-Pin Mil-C-5015 2-Pin Mil-C-5015
Electrical Connection Position Top Top

 

Hazardous Area Approvals

**Note: The 200355 does not have hazardous area approvals at this time.

200350

  North America:

  Ex ia / AEx ia IIC T4

  Class I, Div 1 Groups A, B, C & D

  When installed per dwg 175825

  T4 @ -54 °C = Ta = 121 °C

 

  Ex nL/AEx nA IIC T4

  Class I, Div 2 Groups A, B, C & D

  When installed per dwg 175825

  T4 @ -54 °C = Ta = 121 °C

  CSA 2007 1971585

 

ATEX:

  II 1 G

  Ex ia IIC T4

  LCIE 07 ATEX 6096 X

  T4 @ -54 °C = Ta = 121 °C

 

  II 3 G

  Ex nL IIC T4

  LCIE 07 ATEX 6097 X

  T4 @ -54 °C = Ta = 121 °C

 

Standards to which Conformity is Declared:

  CISPR 11 / EN 55011  Emissions: Class B, Group 1

  EN61326 / A1    Emissions: Industrial Location

  EN61326 / A1    Immunity: Industrial Location